ABBA-RACK PACKAGE
» Closed Rack Package
» Wallmounted Rack Package
CLOSED RACK
» Glass Door
» Perforated Door
» Split Door
» Intelligent Rack
» Biometric Server Rack
WALLMOUNTED RACK
» Single Door
» Double Door
OPEN RACK
» Standard Open Rack
» High Density Open Entry Rack
» 4 Post Open Rack
RACK WITH COOLING
» Closed Rack with Cooling
» Wallmount Rack with Cooling
OUTDOOR CABINET
» Outdoor Standing Closed Rack
» Outdoor Wallmounted Rack
CUSTOMIZED RACK
» Telco and Battery Rack
» Backup Tape Rack
SERVER RACK ACCESSORIES
» KVM and Screen
» UTP & FO Panel
» UTP & FO Patch Cord
» PDU
» Flat Shelf
» Cantilever
» Telescopic Drawer
» Digital Temperature
» Blank Panel
» Wire Management
» Cable Tray
» Cable Duct
» Fan
» Castor, Cage Nut and M6 Screw
DATA CENTER SOLUTIONS
» Cages System
» Colocation Server Rack
» Cold Aisle Containment System
» Environmental Monitoring System
» Raised Floor Mount Fan Unit
AUSTIN HUGHES PRODUCTS
» Rack PDU   :: InfraPower
» Rack Access :: InfraSolution
» Rack Sensor :: InfraGuard
» Rack KVM   :: CyberView
» Rack Airflow :: InfraCool
Door Mount Fan Panel | InfraCool

Austin Hughes InfraCool Door mount fan panel is typically installed on the outside of a rack’s rear perforated door to improve heat extraction from high density rack.

The unit can be attached to most of 42U or taller racks. If aisle is relatively narrow for exterior mounting, the unit may be installed on the inside of the perforated door.

Door Mount Fan Panel Models :


1. Intelligent Door Mount Fan Panel - InfraCool

InfraCool Intelligent Fan Unit series is designed to provide local and remote management capabilities. Up to 16 fan units can be connected by daisy chain and remotely accessed by one single IP address. Maximum 30 x daisy chain group ( i.e. 480 x Fan Unit ) can be remotely managed by the free GUI.

Front panel LED and buttons allow local monitoring and individual fan kit switch on / off. Besides, fan speed can be adjusted automatically according to the temperature detected by the sensor. It provides adequate airflow and minimizes the operational cost for data center energy consumption.

Door Mount Fan Panel Intelligent Fan Unit series offers Master IP and Remote models.

Master IP Fan Unit is bundled with internal IP dongle. Hence, it is applied as the 1st level fan unit in the daisy chain.

Remote Fan Unit without built-in IP dongle will be located to the 2nd to 16th fan unit levels.


distributor rack server, rack airflow booster



air booster, jual rack server


Features & Benefits

Easy installation with common tools

Thin & light weight design only 5 kgs

Designed for low noise & high airflow performance

Improves extraction of heat from high density rack

Cascade ports for daisy chain up to 16 levels via Cat6 cable

1 x intelligent master fan unit allows access to 16 fan unit levels over internet

Free ICM-02 management software remote access up to 480 fan units

Auto & manual CFM setting reduces power consumption

1 x bundled temp. sensor with 2M wire

Temperature sensing technology adjusts the fan speeds accordingly

Unit or individual fan on / off ( remote or local )



air booster, distributor rack server



2. Basic Door Mount Fan Panel - InfraCool

rack airflow booster, jual rack server 20u


Benefits

Easy installation with common tools

Thin & light weight design only 4.6 kgs / 10.1 lbs

Designed for low noise & high airflow performance

Improves extraction of heat from high density rack

External temperature sensor x 1

Front temperature LED

Auto-sensing 110V to 220VAC power input




More Option : Raised Floor Mount Fan Unit »»     Rackmount Fan Tray »»